Static routing is a form of routing that occurs when a router uses a manually-configured routing entry, rather than information from dynamic routing traffic.
Ursalink Industrial Router supports different network access, including the Ethernet, Cellular, VPN and VLAN access, which supports your own rule to send the data to the specific destination server IP through specific gateway.
This is the default routing table when the WAN port was set as the primary link in "Network->Interface" page.
In this example, there is a server address 110.87.98.99, which needs to access through the cellular network. we need to check the Cellular network is connected first. We can find the gateway IP is 10.2.25.72.
Go to "Network->Routing->Static Routing" to add a new route as our example needs.
Click "Save" then you can check the routing table in Status page again.
After adding the route, the router will go through Cellular network directly when you visit the server 110.87.98.99 through it.